Frequently asked questions. We integrate them into selfservice Q&A. You have other questions. you can get in touch with us Or send us an email to:info@xihobattery.com
Please check through the following URL: https://www.17track.net/zh-cn
Unless otherwise requested, the REPT 3.2V 345Ah cells are shipped with a 40% SOC to ensure safety and stability during transportation. This is the ideal state for immediate storage upon arrival.
The REPT 3.2V 345Ah cell has a very low self-discharge rate of ≤3% per month when stored at 25°C and 40% SOC, ensuring it retains most of its energy when not in use for extended periods.
Yes. When integrating the REPT 3.2V 345Ah cell into a battery module, a specific preload force (clamping force) must be applied. The required range is 1500N to 5000N, which is critical for maintaining mechanical integrity, optimal electrical contact, and achieving the advertised cycle life. The cell's dimensions (Thickness: 71.75mm, Width: 174.0mm, Height: 206.8mm) should be used for proper module design.
For long-term storage, the REPT 3.2V 345Ah cell should be kept at an ambient temperature between -10°C to 40°C (with a permissible range of -30°C to 60°C) and at 40% State of Charge (SOC). The environment should be clean, dry, and well-ventilated.
The REPT 3.2V 345Ah cell complies with strict safety standards (GB/T 36276-2023). It has undergone rigorous testing including over-charge, over-discharge, short circuit, squeeze, and drop tests, demonstrating a high level of safety by not catching fire or exploding during these tests.
The REPT 3.2V 345Ah cell is engineered for long-term durability. Under standard test conditions (25±2°C, 0.25P charge/discharge), it delivers a cycle life of ≥8,000 cycles before its capacity degrades to 70% of its original nominal capacity.
Temperature significantly impacts the maximum allowable charging power for the REPT 3.2V 345Ah cell. For example, at 0°C, the max charge power is limited to 0.05P, gradually increasing to the full 0.25P at 20°C and above. Charging is prohibited at 60°C to ensure safety.
You can discharge the REPT 3.2V 345Ah cell at a standard power of 0.25P (276W) down to a cutoff voltage of 2.5V (for temperatures above 0°C). It can operate in a wide temperature range from -20°C to 60°C, making it suitable for various environments.
The standard charging method for the REPT 3.2V 345Ah cell is a Constant Power (CP) charge at 0.25P (276W) until the voltage reaches the upper cutoff of 3.65V. The optimal charging temperature range is between 0°C and 60°C.